Intended use: This device is combined use with endoscope to extract and remove foreign body in digestive tract.

Features:

  • Net design can reduce the risk of foreign body loss, and can be used to take out slithery and complicated foreign bodies;
  • Using imported superfine silk net with good elasticity, high strength and excellent passability;
  • 360 °rotating design brings convenience for clinical operation;
  • Sterile package, disposable.

Intended use: This device is combined use with endoscope to extract and remove foreign body in digestive tract.

Features:

  • The loop is made from imported medical stainless steel wire;
  • 360 °rotating design brings convenience for clinical operation;
  • PTFE sheath ensures smooth, straight, unpliancy and easier entrance of the device;
  • Sterile package, disposable.

Intended use: This device is combined use with endoscope to extract and remove foreign body in digestive tract.

Features:

  • Prongs are made from medical stainless steel wire of good elasticity and high strength;
  • 360 °rotating design brings convenience for clinical operation;
  • Prong type design can effectively grasp the resected polyps without crushing them;
  • Sterile package, disposable.

Intended use: This device is combined use with endoscope to extract and remove foreign body in digestive tract.

Features:

  • Jaws are made from medical stainless steel with good biocompatibility;
  • The head is carefully polished so that less damage is made to endoscope channel;
  • Using four-rod rigid structure of excellent mechanical properties so as to fetch the foreign bodies accurately and firmly;
  • Ultra smooth plastic coating of spring effectively reduces the damage to endoscope channel;
  • Sterile package, disposable.

Kyphoplasty Balloon Catheter (CE MDR Certificate and FDA Approval)

Intended use:

This device is mainly used in Percutaneous Kyphoplasty(PKP) operation to dilate vertebral body and form a cavum which is for injecting bone cement to recover and stabilize vertebral body.

Features:

  • Kyphoplasty Balloon Catheter is designed for correcting compression fractures and restoring vertebral body height. Doctors should choose
    appropriate balloon for dilation according to fracture types;
  • Different OD of the sheath can be applied to different working channel to realize accurate dilation. Different shapes of the balloon can adapt to different thoracic vertebra, lumbar vertebra as well as other types of fractures;
  • The balloon materials feature with excellent characteristics, such as fine supportiveness, biocompatibility, biological persistence, surface anti-biodegradation and environmental stress cracking resistance;
  • Standard four-wing pleating process ensures excellent passability after repeated inflation;
  • Each balloon has passed the pressure and seal test before leaving the factory. Strict quality control measures minimize the risk of balloon burst and leakage.

Specifications:

Model Size Chaneel I.D. Overall Length Maximum Volume PSI Rating Balloon Shape
KB0210S

 

11G

10

 

≥3.1mm

 

280mm

3CC

 

 

400PSI

Cylindrical Type
KB0115S 15 4CC Peanut Type
KB0120S 20 5CC Peanut Type
KB0210

 

8G

10

 

≥3.6mm

 

315mm

4CC Cylindrical Type
KB0115 15 4CC Peanut Type
KB0120 20 6CC Peanut Type

 Customization is also acceptable to our balloons.